Counter Flow Closed Type Cooling Tower

Counter Flow Closed Type Cooling Tower

As the main auxiliary equipment in the heat treatment industry, KBL series counter flow closed type cooling tower is used in heat treatment quenching media, controlled atmosphere multi-purpose furnaces, induction heating furnaces, vacuum furnaces, etc.;

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
Products Description

 

As the main auxiliary equipment in the heat treatment industry, KBL series counter flow closed type cooling tower is used in heat treatment quenching media, controlled atmosphere multi-purpose furnaces, induction heating furnaces, vacuum furnaces, etc.; central air conditioning, forging, casting, chemical industry, food, injection molding, printing, generator sets, power plants, glass melting furnaces, and other fields.

 

product-735-520

 

Operation Principle

 

Working fluid (soft water or other liquid) circulates in the coil of the counter flow closed type cooling tower, the heat of the fluid is absorbed by the wall of the coil, and the spray water is sprayed on the surface of the coil to produce heat exchange. At the same time, the cold air enters the tower from the air inlet grille at the bottom of the unit and circulates from bottom to top, evenly passing through the surface of the coil. A small part of the water evaporates and absorbs the heat, and the hot and humid air is discharged from the machine through the top fan, and the rest of the water falls into the bottom water tray for the next cycle. The fluid closed loop in the coil consumes very little, and the escape rate of the spray water is only 0.1%-0.2%.

product-790-452

 

Features & Advantages

 

* Improve production efficiency, soften water circulation, no scaling, no clogging, no loss;

* Extend the service life of equipment, ensure reliable and stable operation, reduce failure rate and prevent accidents;

* Fully closed-loop circulation, no impurities entering, no medium evaporation, no pollution;

* Improve the utilization rate of the plant, no need for a water tank; reduce the floor space, small space occupation, easy installation, movement, layout, compact structure;

* Easy to operate, stable operation and high degree of automation;

* Widely used, the medium has no corrosion to the heat exchanger, and it can be cooled directly;

* The operation and maintenance cost is low.

 

Technical Parameters

 

Model

Cooling Capacity (Kcal/h)

Working Flow (m³/h)

Dimensions (L*W*H) (mm)

Inlet and Outlet Diameter

KBL-05

150000

30

2800x1870x2450

DN80

KBL-06

180000

36

2800x1870x2450

DN80

KBL-07

225000

45

3400x1970x2600

DN100

KBL-08

260000

52

3400x1970x2600

DN100

KBL-09

300000

60

3400x1970x2600

DN100

KBL-10

350000

70

3400x1970x3250

DN125

KBL-12

400000

80

3400x1970x3250

DN125

KBL-13

450000

90

3400x1970x3250

DN125

KBL-14

500000

100

3400x2340x3250

DN125

KBL-15

550000

110

3400x2340x3250

DN125

KBL-16

600000

120

4200x2340x3350

DN150

KBL-17

650000

130

4200x2340x3350

DN150

KBL-18

700000

140

4200x2340x3350

DN150

KBL-19

750000

150

4200x2340x3350

DN150

KBL-20

800000

160

4800x2340x4200

DN200

KBL-21

900000

180

4800x2340x4200

DN200

KBL-22

1000000

200

4800x2340x4200

DN200

KBL-23

1100000

220

4800x2340x4200

DN200

KBL-24

1200000

240

5350x2340x4300

DN200

KBL-25

1300000

260

5350x2340x4300

DN200

KBL-26

1400000

280

6100x2340x4250

DN250

KBL-27

1500000

300

6100x2340x4250

DN250

KBL-28

1700000

340

5350x3200x4650

DN250

KBL-30

1900000

380

5350x3200x4650

DN250

KBL-32

2100000

420

5800x3200x4650

DN250

KBL-34

2500000

500

6500x3200x4700

DN300

KBL-36

2800000

560

6500x3200x4700

DN300

Note: The above technical parameters are for reference only: because the products are constantly updated and optimized, the parameters are subject to change without prior notice.

 

Non-standard Design

 

product-725-556

 

Precautions For The Use of Closed Type Cooling Tower

 

1. Requirements for The Using Environment

* Avoid acidic exhaust gas, explosive dust, severe soot, and excessive water vapor;

* Placed next to a building, it should be kept enough distance from the air inlet (0.5-3M, depending on the model);

* Placed in the pit fence wall, it should be alert of heat discharge fault caused by hot and humid air reflow; an air induced device may be considered under special circumstances.

 

2. User Piping Problems

* Piping, pumps and valves should be installed below the running water level of the cooling tower to prevent overflow and air intake;

* When considering the equipment placement, there should be enough water pump head and the pressure loss to the head and pressure loss to the cooling coil pipe should be taken into account;

* The design pressure of interface flange for fluid cooling is 1MPa, and hangers or supports should be considered for all pipelines.

 

3. Maintenance Requirements of Spraying System

* As the closed cooling tower runs, minerals and other impurities in the water will precipitate and accumulate in the tank, so we must periodically check the water quality and blow down and clean on a regular basis, this can well control the water quality and prevent scaling.

* Requirements of spraying water quality: refer to GB50050-95 Code for design of industrial recirculating cooling water treatment; where there is water with specially poor quality, the purification (softening) shall be considered.

 

4. Supplement of Recirculating Water

* The recirculating water in the closed system should meet the requirements of production process for water quality, and softened water or purified water can be used.

* The closed system is equipped with a liquid level control system; if the system gives out a warning message, the level of recirculating water is low, and we need to add recirculating water.

 

5. Maintenance and Cleanup of Spraying Tank

* Note: the spraying water should be replaced periodically, and the spraying tank should be cleaned regularly.

* There are differences in water hardness in regions. Namely, it is recommended that the spraying water is replaced and the tank is cleaned up once every 5-6 months in the southern regions. In the northern regions, it is recommended that the spraying water is replaced and the tank is cleaned up once every 2-3 months. The actual replacement time shall be as the case may be.

 

6. Anti-freezing Problem of Closed Cooling Tower

* The anti-freezing measures for closed type cooling tower are generally classified into two categories:

(1). According to the temperature differences in regions, add anti-freezing solution according to the ratio.

(2.) Where the temperature is low, when the equipment does not run for a short time or stops running, the spraying water should be discharged to prevent freezing.

 

Ratio Table of Antifreezing Solution

 

Ethylene glycol ( wt%)

0

10

20

30

40

50

58

Fixed point (℃)

-0.0

-3.5

-8

-15

-24

-36

-48

 

Hot Tags: counter flow closed type cooling tower, China counter flow closed type cooling tower manufacturers, suppliers, factory, Cross Flow Closed Circuit Cooling Tower, Countercurrent Closed Cooling Tower, Closed Type Crossflow Cooling Tower, Counter Flow Closed Circuit Cooling Tower, Counter Flow Closed Cooling Tower, Crossflow Open Type Cooling Tower