Counter Flow Closed Circuit Cooling Tower
video
Counter Flow Closed Circuit Cooling Tower

Counter Flow Closed Circuit Cooling Tower

KBL Series counter flow closed circuit cooling tower with excellent cooling effect, low noise design, efficient energy saving and lower operating cost, corrosion resistance, long service life, low power consumption, and other advantages, has a great leaping forward compared to conventional cooling towers.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
Products Description

 

KBL Series counter flow closed circuit cooling tower with excellent cooling effect, low noise design, efficient energy saving and lower operating cost, corrosion resistance, long service life, low power consumption, and other advantages, has a great leaping forward compared to conventional cooling towers. In order to meet the needs of modern industry development, the closed circuit cooling tower tested in practice has been widely used in automobile, plane, ship, electric power, chemical industry, food, medical treatment, central air conditioning, forging, casting, heat treatment, experiment platform, and other industries.

 

product-800-600

 

Operation Principle

 

The operating principle of the counter flow closed cooling tower is as follows: The working fluid (soft water or other liquids) circulates in the coil pipe of the counterflow closed circuit cooling tower, the fluid heat is absorbed by the coil pipe wall, the spraying water is sprayed onto the coil pipe surface to exchange heat, and meanwhile the cool air flows from the air intake grill at the bottom of the unit into the tower to circulate from bottom to top, and to flow evenly through the coil pipe surface. A small part of the water is evaporated while heat is absorbed, and the hot and humid air is discharged outside through the top fan, while the rest of the water falls onto the water disk at the bottom for the next recirculating. Since the fluid in the coil pipe is in a closed recirculating, the consumption is very little, and the flowing rate of spraying water is only 0.1%-0.2%.

product-790-452

 

Features & Benefits

 

* The cooling tower's center of gravity moves down, with a stable structure and strong wind resistance.

* Spraying water has good cooling effect, and the internal recirculating water has high heat transfer efficiency, thus saving energy.

* The lower box is equipped with a maintenance channel, easy to repair, clean and maintain the heat exchanger and to improve the service life of the heat exchanger.

* Fan-side (opposed to the heat exchanger) air duct is smooth, easy to remove hot air.

* A specially designed anti-floating water filler saves a lot of water resources for customers.

* Apron disks distribute water uniformly, so the problem of uneven water spraying is well solved and the heat exchange effect is better.

* The upper and lower boxes are designed with a frame structure, and it is easy to maintain and replace all parts, which can extend the life of the counter flow closed circuit cooling tower.

* Protective fence and maintenance ladder are positioned at top of the tower, easy for the maintenance staff to maintain on the tower top.

* A spraying water cooling component is added, thus reducing spraying water temperature, ensuring the cooling effect and improving the cooling ability of the cooling tower.

* Combined use of low power fans is made, and the number of fans to start-stop is automatically controlled with the effective temperature range, saving energy and reducing operating costs. Even in the event of fan failure, it does not affect the cooling tower at work. A direct-coupled axial flow fan is adopted, and its overall is fixed inside the air duct, with no belt aging, relaxation, bearing life limitation and other problems. Therefore it can ensure that the fan's ability to work does not lower down for a long time and that the fan is stable and durable.

* The flow direction and utilization rate of fresh air are fully considered, and the distance between air inlet and outlet is widened, preventing the hot and humid outlet air and inlet air forming a loop, and preventing hot air flowing directly back into the air inlet, resulting in decreased heat rate and energy waste and so on.

* A new meter cooler is designed with anti-freeze type. Each row of coil pipe has a certain slope to ensure that in the equipment downtime in winter, residual cool water in the coil pipe can empty from top to bottom, resolving the problem that the liquid in horizontal coil pipe can not be discharged completely in winter, resulting in the coil pipe burst due to freezing.

* The cooler of KBL counter flow closed circuit cooling tower is located at the bottom of the whole equipment, and it can be seen while entering the access door; moreover, there is no filler between the upper and lower coil pipes, easy for technician to maintain the coil pipes, so there is no necessity to dismantle and wash the filler.

 

Technical Parameters

 

Model

Cooling Capacity (Kcal/h)

Working Flow (m³/h)

Dimensions (L*W*H) (mm)

Inlet and Outlet Diameter

KBL-05

150000

30

2800x1870x2450

DN80

KBL-06

180000

36

2800x1870x2450

DN80

KBL-07

225000

45

3400x1970x2600

DN100

KBL-08

260000

52

3400x1970x2600

DN100

KBL-09

300000

60

3400x1970x2600

DN100

KBL-10

350000

70

3400x1970x3250

DN125

KBL-12

400000

80

3400x1970x3250

DN125

KBL-13

450000

90

3400x1970x3250

DN125

KBL-14

500000

100

3400x2340x3250

DN125

KBL-15

550000

110

3400x2340x3250

DN125

KBL-16

600000

120

4200x2340x3350

DN150

KBL-17

650000

130

4200x2340x3350

DN150

KBL-18

700000

140

4200x2340x3350

DN150

KBL-19

750000

150

4200x2340x3350

DN150

KBL-20

800000

160

4800x2340x4200

DN200

KBL-21

900000

180

4800x2340x4200

DN200

KBL-22

1000000

200

4800x2340x4200

DN200

KBL-23

1100000

220

4800x2340x4200

DN200

KBL-24

1200000

240

5350x2340x4300

DN200

KBL-25

1300000

260

5350x2340x4300

DN200

KBL-26

1400000

280

6100x2340x4250

DN250

KBL-27

1500000

300

6100x2340x4250

DN250

KBL-28

1700000

340

5350x3200x4650

DN250

KBL-30

1900000

380

5350x3200x4650

DN250

KBL-32

2100000

420

5800x3200x4650

DN250

KBL-34

2500000

500

6500x3200x4700

DN300

KBL-36

2800000

560

6500x3200x4700

DN300

Note: The above technical parameters are for reference only: because the products are constantly updated and optimized, the parameters are subject to change without prior notice.

 

Non-standard Design

 

product-725-556

According to different technical requirements of customers, KEJU can provide you with specialized non-standard designs.

 

Project Reference Of KBL Series

 

product-773-493

 

Hot Tags: counter flow closed circuit cooling tower, China counter flow closed circuit cooling tower manufacturers, suppliers, factory, Open Circuit Cross Flow Square Cooling Tower, Countercurrent Closed Cooling Tower, Counter Flow Closed Cooling Tower, Counter Flow Closed Type Cooling Tower, Cross Flow Steel Open Cooling Tower, closed circuit cooling tower

You Might Also Like

(0/10)

clearall