Counter Flow Closed Water Cooling Tower

Counter Flow Closed Water Cooling Tower

KBL series counter flow closed water cooling tower is made in special alloy coated steel or stainless steel, Heat exchange coils made in stainless steel or red copper.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
Product Description

 

KBL series counter flow closed water cooling tower is made in special alloy coated steel or stainless steel, Heat exchange coils made in stainless steel or red copper. KBL series counter flow cooling towers are more compact, occupy less installation space, work without any wet deck fill, and are more suitable for cooling hot water with higher inlet temperature. The tower size can be customized according to standard containers or specific project conditions.

KBL series closed circuit counter flow cooling towers are widely applied in different fields, to cool circulating water, oil, or other process fluid for melting/ vacuum/ multi-crystal furnaces, induction heaters, compressors, heat pumps, metal parts production lines, hydraulic stations, power generators, transformers, converters, etc.

 

product-800-679

 

Configurations of Counter Flow Closed Water Cooling Tower

 

product-293-243

Red Copper Heat Exchanger

According to the international standard, it is produced by T2 depickling red copper tube with purity 99.9%, with high heat transfer efficiency. A mode of staggered arrangement is adopted, increasing the heat transfer efficiency, and reducing the pressure drop in air flowing through the unit. The installed coil pipe is put into 1.2Mpa air pressure test in water to ensure that there is no leakage.

Stainless Steel Heat Exchanger

Made of 304 or 316L standard pipe, it adapts to the environment. A mode of staggered arrangement is adopted, increasing the heat transfer efficiency, and reducing the pressure drop in air flowing through the unit. The installed coil pipe is put into 1.2Mpa air pressure test in water to ensure that there is no leakage.

product-293-243

product-293-271

Electrical Control Cabinet

Electrical control cabinet is suitable for outdoor applications, and PLC control mode can be used.

Water Replenishing Inlet

To be controlled by stainless steel ball float valve.

product-293-271

product-293-244

Exhaust System

Three-prevent aluminum casing fan is adopted and installed in a special induced air tube, and a hot-dip galvanized steel wire mesh cover is arranged at its top for protection. The protection class of the fan motor is IP55, and the insulation class is level F.

Water Defector (Dehydrater)

Made from PVC material, it is grouped and installed inside the unit. The dehydrator is three-change designed to ensure that the water in the airflow can be blocked, so that the maximum drift rate of moisture is less than 0.1 per thousand of the volume of recirculating water.

product-293-244

product-293-272

Air Intake Grill

It is constructed by PVC material, and installed on the frame around the unit which is easily disassembled and assembled, so that the heat exchanger can be maintained. The grille is designed with two air changes to prevent splashing the sink and being exposed to direct sunlight. It has an air deceleration zone, by which air can be effectively led to the fan.

Spraying System

A vertical centrifugal pump is applied to provide adequate spraying water, to ensure that the whole set of coil pipe is fully contained in the water flow. Spraying pipe is manufactured with standard PVC material, with corrosion resistance.

product-293-272

 

Technical Parameters

 

Model

Cooling Capacity (Kcal/h)

Working Flow (m³/h)

Dimensions (L*W*H) (mm)

Inlet and Outlet Diameter

KBL-05

150000

30

2800x1870x2450

DN80

KBL-06

180000

36

2800x1870x2450

DN80

KBL-07

225000

45

3400x1970x2600

DN100

KBL-08

260000

52

3400x1970x2600

DN100

KBL-09

300000

60

3400x1970x2600

DN100

KBL-10

350000

70

3400x1970x3250

DN125

KBL-12

400000

80

3400x1970x3250

DN125

KBL-13

450000

90

3400x1970x3250

DN125

KBL-14

500000

100

3400x2340x3250

DN125

KBL-15

550000

110

3400x2340x3250

DN125

KBL-16

600000

120

4200x2340x3350

DN150

KBL-17

650000

130

4200x2340x3350

DN150

KBL-18

700000

140

4200x2340x3350

DN150

KBL-19

750000

150

4200x2340x3350

DN150

KBL-20

800000

160

4800x2340x4200

DN200

KBL-21

900000

180

4800x2340x4200

DN200

KBL-22

1000000

200

4800x2340x4200

DN200

KBL-23

1100000

220

4800x2340x4200

DN200

KBL-24

1200000

240

5350x2340x4300

DN200

KBL-25

1300000

260

5350x2340x4300

DN200

KBL-26

1400000

280

6100x2340x4250

DN250

KBL-27

1500000

300

6100x2340x4250

DN250

KBL-28

1700000

340

5350x3200x4650

DN250

KBL-30

1900000

380

5350x3200x4650

DN250

KBL-32

2100000

420

5800x3200x4650

DN250

KBL-34

2500000

500

6500x3200x4700

DN300

KBL-36

2800000

560

6500x3200x4700

DN300

Note: The above technical parameters are for reference only: because the products are constantly updated and optimized, the parameters are subject to change without prior notice.

 

Working Theory

 

The operating principle of the counter flow closed water cooling tower is as follows: The working fluid (soft water or other liquids) circulates in the coil pipe of the counterflow closed circuit cooling tower, the fluid heat is absorbed by the coil pipe wall, the spraying water is sprayed onto the coil pipe surface to exchange heat, and meanwhile the cool air flows from the air intake grill at the bottom of the unit into the tower to circulate from bottom to top, and to flow evenly through the coil pipe surface. A small part of the water is evaporated while heat is absorbed, and the hot and humid air is discharged outside through the top fan, while the rest of the water falls onto the water disk at the bottom for the next recirculating. Since the fluid in the coil pipe is in a closed recirculating, the consumption is very little, and the flowing rate of spraying water is only 0.1%-0.2%.

product-790-452

 

Features & Advantages

 

* Compatible with numerous process fluids (water, water/glycol, oil, other fluids)

* Capable and flexible in customized solutions

* Factory assembled for maximal installation convenience

* Modular design suits a wide range of heat rejection duties

* Compact design with minimal footprints

* Multiple corrosion resistant options

* Low sound operation options available

* Super long service life

 

Application Area

 

product-800-893

product-800-893

 

Hot Tags: counter flow closed water cooling tower, China counter flow closed water cooling tower manufacturers, suppliers, factory, Counterflow Induced Draft Closed Cooling Tower, Cross Flow Closed Loop Cooling Tower, Open Circuit Evaporative Cooling Tower, open circuit cooling tower, Cross Flow Closed Water Cooling Tower, cooling tower accessories

You Might Also Like

(0/10)

clearall