Counterflow Induced Draft Closed Cooling Tower

Counterflow Induced Draft Closed Cooling Tower

This type of cooling tower operates by drawing hot water from industrial processes, circulating it through heat exchangers, and then releasing it back into the industrial process after it has been cooled.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
Product Description

 

KBL series counterflow induced draft closed cooling tower is an advanced cooling system used in various industrial and commercial settings. This type of cooling tower operates by drawing hot water from industrial processes, circulating it through heat exchangers, and then releasing it back into the industrial process after it has been cooled. This is achieved through a series of counterflow tubes and an induced draft fan that draws air through the tower, cooling the process water. This type of cooling tower requires minimal water usage and can save a significant amount of energy compared to traditional open cooling systems. Additionally, because it is a closed system, it is safer for the environment and reduces the potential for contamination or pollution.

 

product-800-679

 

Features & Benefits

 

* No Contamination of The Primary Circuit: Many civil and industrial processes require keeping the process fluid free from contamination from the external environment: this is the case, for example, with most food production processes. Closed-circuit cooling towers meet this need: in practice, the coils separate the process fluid from the ambient air sucked in by the fan, keeping it clean and free of contamination in a closed loop.

* Reduction of Freezing Risk: Since the process water circulates in the heat exchange coil and never comes in contact with the air, glycol can be added to it to lower the fluid freezing point. This is a huge advantage especially in cold countries where temperatures often drop below zero degrees.

* Easier plant layout

* Reduced footprint

* Higher thermal efficiency

 

Technical Parameters

 

Model

Cooling Capacity (Kcal/h)

Working Flow (m³/h)

Dimensions (L*W*H) (mm)

Inlet and Outlet Diameter

KBL-05

150000

30

2800x1870x2450

DN80

KBL-06

180000

36

2800x1870x2450

DN80

KBL-07

225000

45

3400x1970x2600

DN100

KBL-08

260000

52

3400x1970x2600

DN100

KBL-09

300000

60

3400x1970x2600

DN100

KBL-10

350000

70

3400x1970x3250

DN125

KBL-12

400000

80

3400x1970x3250

DN125

KBL-13

450000

90

3400x1970x3250

DN125

KBL-14

500000

100

3400x2340x3250

DN125

KBL-15

550000

110

3400x2340x3250

DN125

KBL-16

600000

120

4200x2340x3350

DN150

KBL-17

650000

130

4200x2340x3350

DN150

KBL-18

700000

140

4200x2340x3350

DN150

KBL-19

750000

150

4200x2340x3350

DN150

KBL-20

800000

160

4800x2340x4200

DN200

KBL-21

900000

180

4800x2340x4200

DN200

KBL-22

1000000

200

4800x2340x4200

DN200

KBL-23

1100000

220

4800x2340x4200

DN200

KBL-24

1200000

240

5350x2340x4300

DN200

KBL-25

1300000

260

5350x2340x4300

DN200

KBL-26

1400000

280

6100x2340x4250

DN250

KBL-27

1500000

300

6100x2340x4250

DN250

KBL-28

1700000

340

5350x3200x4650

DN250

KBL-30

1900000

380

5350x3200x4650

DN250

KBL-32

2100000

420

5800x3200x4650

DN250

KBL-34

2500000

500

6500x3200x4700

DN300

KBL-36

2800000

560

6500x3200x4700

DN300

Note: The above technical parameters are for reference only: because the products are constantly updated and optimized, the parameters are subject to change without prior notice.

 

Application Area

 

product-800-893

product-800-893

 

Hot Tags: counterflow induced draft closed cooling tower, China counterflow induced draft closed cooling tower manufacturers, suppliers, factory, Cross Flow Closed Cooling Tower, Counterflow Induced Draft Closed Cooling Tower, Cross Flow Closed Circuit Cooling Tower, Counter Flow Closed Cooling Tower, Closed Circuit Cross Flow Cooling Tower, Countercurrent Closed Cooling Tower