
Counterflow Induced Draft Closed Cooling Tower
This type of cooling tower operates by drawing hot water from industrial processes, circulating it through heat exchangers, and then releasing it back into the industrial process after it has been cooled.
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
Product Description
KBL series counterflow induced draft closed cooling tower is an advanced cooling system used in various industrial and commercial settings. This type of cooling tower operates by drawing hot water from industrial processes, circulating it through heat exchangers, and then releasing it back into the industrial process after it has been cooled. This is achieved through a series of counterflow tubes and an induced draft fan that draws air through the tower, cooling the process water. This type of cooling tower requires minimal water usage and can save a significant amount of energy compared to traditional open cooling systems. Additionally, because it is a closed system, it is safer for the environment and reduces the potential for contamination or pollution.

Features & Benefits
* No Contamination of The Primary Circuit: Many civil and industrial processes require keeping the process fluid free from contamination from the external environment: this is the case, for example, with most food production processes. Closed-circuit cooling towers meet this need: in practice, the coils separate the process fluid from the ambient air sucked in by the fan, keeping it clean and free of contamination in a closed loop.
* Reduction of Freezing Risk: Since the process water circulates in the heat exchange coil and never comes in contact with the air, glycol can be added to it to lower the fluid freezing point. This is a huge advantage especially in cold countries where temperatures often drop below zero degrees.
* Easier plant layout
* Reduced footprint
* Higher thermal efficiency
Technical Parameters
|
Model |
Cooling Capacity (Kcal/h) |
Working Flow (m³/h) |
Dimensions (L*W*H) (mm) |
Inlet and Outlet Diameter |
|
KBL-05 |
150000 |
30 |
2800x1870x2450 |
DN80 |
|
KBL-06 |
180000 |
36 |
2800x1870x2450 |
DN80 |
|
KBL-07 |
225000 |
45 |
3400x1970x2600 |
DN100 |
|
KBL-08 |
260000 |
52 |
3400x1970x2600 |
DN100 |
|
KBL-09 |
300000 |
60 |
3400x1970x2600 |
DN100 |
|
KBL-10 |
350000 |
70 |
3400x1970x3250 |
DN125 |
|
KBL-12 |
400000 |
80 |
3400x1970x3250 |
DN125 |
|
KBL-13 |
450000 |
90 |
3400x1970x3250 |
DN125 |
|
KBL-14 |
500000 |
100 |
3400x2340x3250 |
DN125 |
|
KBL-15 |
550000 |
110 |
3400x2340x3250 |
DN125 |
|
KBL-16 |
600000 |
120 |
4200x2340x3350 |
DN150 |
|
KBL-17 |
650000 |
130 |
4200x2340x3350 |
DN150 |
|
KBL-18 |
700000 |
140 |
4200x2340x3350 |
DN150 |
|
KBL-19 |
750000 |
150 |
4200x2340x3350 |
DN150 |
|
KBL-20 |
800000 |
160 |
4800x2340x4200 |
DN200 |
|
KBL-21 |
900000 |
180 |
4800x2340x4200 |
DN200 |
|
KBL-22 |
1000000 |
200 |
4800x2340x4200 |
DN200 |
|
KBL-23 |
1100000 |
220 |
4800x2340x4200 |
DN200 |
|
KBL-24 |
1200000 |
240 |
5350x2340x4300 |
DN200 |
|
KBL-25 |
1300000 |
260 |
5350x2340x4300 |
DN200 |
|
KBL-26 |
1400000 |
280 |
6100x2340x4250 |
DN250 |
|
KBL-27 |
1500000 |
300 |
6100x2340x4250 |
DN250 |
|
KBL-28 |
1700000 |
340 |
5350x3200x4650 |
DN250 |
|
KBL-30 |
1900000 |
380 |
5350x3200x4650 |
DN250 |
|
KBL-32 |
2100000 |
420 |
5800x3200x4650 |
DN250 |
|
KBL-34 |
2500000 |
500 |
6500x3200x4700 |
DN300 |
|
KBL-36 |
2800000 |
560 |
6500x3200x4700 |
DN300 |
Note: The above technical parameters are for reference only: because the products are constantly updated and optimized, the parameters are subject to change without prior notice.
Application Area


Hot Tags: counterflow induced draft closed cooling tower, China counterflow induced draft closed cooling tower manufacturers, suppliers, factory, Cross Flow Closed Cooling Tower, Counterflow Induced Draft Closed Cooling Tower, Cross Flow Closed Circuit Cooling Tower, Counter Flow Closed Cooling Tower, Closed Circuit Cross Flow Cooling Tower, Countercurrent Closed Cooling Tower
No Information







