Square Crossflow Open Circuit Cooling Tower
KHLT Series square crossflow open circuit cooling tower is a type of cooling tower that uses evaporation to remove heat from a building or industrial process. These towers have a square shape and utilize a crossflow design in which the water flow is horizontal and the air flow is vertical. This design allows for efficient heat transfer and optimal performance.
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
Product Description
KHLT Series square crossflow open circuit cooling tower is a type of cooling tower that uses evaporation to remove heat from a building or industrial process. These towers have a square shape and utilize a crossflow design in which the water flow is horizontal and the air flow is vertical. This design allows for efficient heat transfer and optimal performance.
Open circuit cooling towers are operated in a way that the cooling water comes into contact with the air. The water is exposed to the ambient air, and heat is transferred by evaporation. The cooled water is then circulated back into the process or building to remove more heat. In this way, open circuit cooling towers are very effective at removing heat from an industrial process or building.
The square design of the cooling tower also allows for easy maintenance and cleaning. The tower is made up of modular components that are easy to access for maintenance and repair. This makes it easy to keep the tower running efficiently and effectively.


Structural Features
* High heat transfer efficiency, rapid cooling, and high utilization efficiency of circulating water.
* The tower body, water tank, bracket, and air duct are all made of steel materials with high strength.
* Simple structure, easy to clean and repair, reducing equipment downtime.
* Environmentally friendly materials, no pollution to the environment, and lower purchase cost.
* Each component adopts domestic or international first-line brand configuration, which is durable and long-lasting.
Technical Parameters


Use and Maintenance of KHLT Crossflow Open Circuit Cooling Tower
* Before starting, the inlet and outlet pipes and water basin should be fully cleaned to check whether the fasteners of the transmission parts are firm and whether the impeller is flexible. Check whether the transmission joint is safe.
* The fan turns clockwise and needs to be started at reduced voltage. Check whether the current, voltage and vibration of the motor are normal.
* After the synchronous belt drive deceleration fan has been running for a period of time, the tension should be readjusted.
* After the fan is running normally, start the circulation pump, close the tower outlet valve first, and then open it after the water level line of the water basin is reached, and put it into normal operation. The operation should maintain a corresponding water level line.
* The water quality of the tower is required to be free of oil and impurities, and the turbidity is ≥5mg/kg, otherwise it must be equipped with water treatment and purification equipment.
* Regularly maintain the equipment once a year to remove dirt from the water basin. Adjust the belt tension regularly. If there is dirt in the packing shell, remove it in time, generally once a year.
Hot Tags: square crossflow open circuit cooling tower, China square crossflow open circuit cooling tower manufacturers, suppliers, factory, cooling tower accessories, open circuit cooling tower, Counter Flow Closed Circuit Cooling Tower, cooling tower collaboration, Electrical Control Cabinet for Cooling Tower, Cross Flow Closed Circuit Cooling Tower